TFACE S - Facade system

*Other colors on request
Insulation
PUR
PIR
MW
Junction
Junction

When aesthetics is of the utmost importance, the best panels to choose are TFace S – wall sandwich panels system with secret fix. The various profiles of the sheet metal and the lack of visible screws on the facade make them suitable for industrial and public buildings  with modern design. They are suitable for almost any building that requires good insulation qualities, quick installation and a memorable design.





Insulation PUR
Insulation PIR
Insulation MW
Panel thickness (mm) 40 50 60 80 100 120 150
Extrenal sheet thickness (mm) 0.50 0.50 0.50 0.50 0.50 0.50 0.50
Internal sheet thickness (mm) 0.40 0.40 0.40 0.40 0.40 0.40 0.40
Panel weight (kg/m2) 9.36 9.72 10.08 10.08 11.52 12.24 13.32
Thermal conductivity coefficient λ(W/mK) 0.023 W/mK
Coefficient of thermal transmittance U(W/m2K) 0.52 0.43 0.36 0.27 0.22 0.19 0.15
Class of reaction to fire   F
Fire resistance (min) - - - - - - -

 

Panel thickness (mm) 50 60 80 100 120 150
Extrenal sheet thickness (mm) 0.60 0.60 0.60 0.60 0.60 0.60
Internal sheet thickness (mm) 0.40 0.40 0.40 0.40 0.40 0.40
Panel weight (kg/m2) 10.88 11.29 12.11 12.93 13.75 14.98
Thermal conductivity coefficient λ(W/mK) 0.022 W/mK
Coefficient of thermal transmittance U(W/m2K) 0.41 0.35 0.26 0.21 0.18 0.14
Class of reaction to fire   Bs1, d0
Fire resistance (min) - - EI30 EI30 EI30 EI30

 

Panel thickness (mm) 50 60 80 100 120 150
Extrenal sheet thickness (mm) 0.50 0.50 0.50 0.50 0.50 0.50
Internal sheet thickness (mm) 0.50 0.50 0.50 0.50 0.50 0.50
Insulation core density (kg/m3) 100 kg/m3
Panel weight (kg/m2) 14.23 15.23 17.23 19.23 21.23 24.23
Thermal conductivity coefficient λ(W/mK) 0.041 W/mK
Coefficient of thermal transmittance U(W/m2K) 0.72 0.61 0.47 0.38 0.32 0.26
Class of reaction to fire   A2-s1, d0
Fire resistance (min) EI60 EI60 EI60 EI60 EI60 EI60

 